Pool heater function verified so that permit can be modified back to year round. Heater not required until November 1st till March 31st!
0.0
5.
Must have readings 2x/7days a week!
0.0
11.
Handrail in middle of steps from sun shelf may not meet code in 2025, but would be grandfathered.
0.0
17.
Steps to clubhouse are not evenly spaced, causing a minor trip hazard. Needs to be addressed if possible!
0.0
22.
Kings III phone using cell service, auto answering on 4th ring! See if carrier can modify to 6 ring.
0.0
24.
47,000 gal; 131gpm min turnover flowrate. Hayward pump is for the filtration system. Pentair WFE-8 2 HP pump is for the feature.
0.0
General Comments
Modified permit from seasonal to year round outdoor pool.
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Night swimming allowed as per conditions on the permit.
Heater is not functional at this time. Working to fix, so will modify permit to year round when repaired.
0.0
5.
Must have readings 2x/day 6hrs apart 7days a week.
0.0
6.
Hayward pump is for the filtration system. Pentair WFE-8 2 HP pump is for the feature.
0.0
18.
ADULTS SHOULD NOT SWIM ALONE and CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION are required in 1 inch letters as per NC State and WCES rules! Signs must be visible from all entrances! Signs corrected during the inspection. Points taken but not closing! Additional warning signs of any wordage and size can be displayed as per property management requirements.
4.0
21.
Night lighting could not be activated during daytime, so could not be approved. Night visit is required.
0.0
22.
Add pool to the secondary address line at 911.
0.0
24.
47,000 gal; 131gpm min turnover flowrate
0.0
General Comments
Issued seasonal outdoor pool permit with conditions!
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.