Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 05/08/2024
Score: 2
#
Comments
Points
11.
The ladder disks are broken off and need to be sealed back to the ground.- Ladders shall be in good repair
2.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 05/11/2023
Score: 14
#
Comments
Points
7.
Pool floors have sand on the bottom and need cleaned.- Pool floors shall be kept clean.- Please clean the pool floors.
4.0
22.
The 911 operator does not have the correct phone number for the pool.- Emergency phone shall be working properly with 911 matching the correct location and phone number.- CORRECTED DURING INSPECTION. The phone number was updated during my visit. Permit issued.
6.0
24.
The flow meter is broken and not working.- Flow meter shall be operating properly.- Please replace the flow meter.
4.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 05/12/2022
Score: 16
#
Comments
Points
8.
Many skimmers had plant debris in them, and several weirs were missing...Surface skimmers shall be maintained clean, and weirs shall be present and working properly...Clean the skimmers and replace weirs.
4.0
11.
One handrail closest to the slide was loose...Handrails shall be maintained in good repair...Tighten the handrail.
2.0
16.
Many vertical fence members were wider than 4 inches apart...The spacing between vertical fence posts shall not exceed 4 inches...Repair fence posts so they are no wider than 4 inches apart.
4.0
24.
Flow meter: 425 gpm
0.0
25.
In chemical room, chemicals were stored only 8 inches above floor...Chemicals shall be stored at least 12 inches above floor...Elevate chemicals at least 12 inches above floor.
2.0
29.
Hot water in both men`s and women`s bathrooms exceeded 110F (reached 121F in men`s bathroom)...Hot water must not exceed 110F at sinks and showers in bath/shower rooms...Adjust hot water temperature to 110F or less.
2.0
30.
Hose bib in men`s bathroom did not have a backflow preventer attached...Hose bibs shall have a backflow preventer present...Provide a backflow preventer for hose bib.
2.0
General Comments
>>Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Written VGB information reflects equipment installed. New permit issued today. No night swimming allowed.
Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 04/27/2021
Score: 16
#
Comments
Points
7.
.2537 Portions of plaster missing from pool floor in the area where the slide enters the pool. Leaves on the pool floor. Pool walls and floor shall be kept clean and in good repair. Vacuum and repair floor.
4.0
11.
Handrail to ladder closest to the slide in the 5.5ft area is loose. Handrails and ladders shall be in good repair. Tighten handrail.
2.0
15.
Ring buoy ropes and throw ropes brittle, dry rot and breaking. CPO states that the pool is life guarded at all times, no breaks. Life saving equipment shall be maintained in good repair. Replace ring buoy and 50 foot throw ropes.
0.0
16.
.2528 (3) Three locations in the fence were bent creating a gap up to 7 inches between the vertical members. Where the barrier is composed of horizontal and vertical members and the distance between the tops
of the horizontal members is 45 inches or more, spacing between the vertical members shall not
exceed four inches. Bars bent into proper position during inspection.
4.0
22.
Description of phone for operator is "YMCA". Change description to be "YMCA Pool Phone"
0.0
24.
Flow meter not functioning. Flow meter shall be operating properly. Adjust flow meter so that it works.
4.0
29.
.2526 (i) Shower in mens and womens bathroom reached at least 118F. Pollen on sinks, toilets and floors. The water heater shall be inaccessible to users. The system shall be designed such that water temperature at the
shower heads and lavatories cannot exceed 110° Fahrenheit. Fixtures shall be clean. Adjust water temperature and clean.
2.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
No night swimming. Remove ice machine from pump room. Ice is a food and subject to chemical contamination.
Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 04/22/2020
Score: 10
#
Comments
Points
7.
Remove debris from pool floor. Pool floors shall be kept clean.
4.0
8.
Missing weirs in the skimmers located in the 3 foot and 3 1/2 foot sections of pool. Surface skimmers shall have weirs.
4.0
29.
One shower head is not working in the men`s dressing room. Toilets, hand sinks are dirty in the men`s and women`s and family restroom. Fixtures shall be clean and in good repair.
2.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
This pool must remain closed until the local and state closure orders currently in effect as a result of the COVID-19 pandemic are terminated.
No night swimming.
Pool staff and patrons are strongly encouraged to comply with the most current CDC guidance concerning social distancing related to the COVID-19 pandemic.
Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 05/15/2019
Score: 6
#
Comments
Points
7.
Remove debris from pool floor.
4.0
27.
Backwash must have 3 inch air gap.
2.0
General Comments
Wake County Plan Review and Recreational Sanitation Section recommends pools be hyper chlorinated at least twice a month. This activity should be accurately logged on the CPO check list form.
Location: 494 Knightdale Station Run KNIGHTDALE, NC 27545 Facility Type: Seasonal Swimming Pools Inspection Date: 05/17/2017
Score: 4
#
Comments
Points
8.
A few skimmers contained dead bugs and other buildup. Ensure that these skimmers are being kept clean and maintained.
4.0
15.
Body hook screw was slightly loose. Hook was tighten during the permitting. Ensure that Body hook equipment stay in sturdy condition.
0.0
22.
Emergency phone had the number to the customer service line instead of the direct pool phone line. Number was adjusted so that the direct pool line is what`s visible to the public and not the customer service line.
0.0
General Comments
Ensure that the pool is being hyper-chlorinated weekly to avoid complications dealing with crypto. New Permit issued.